This Mid-Wave infrared camera for industrial temperature detection uses an uncooled focal plane detector ,it is designed for high-temperature and harsh environments, without the common lifespan limitations of traditional cooled devices. The mid-wave infrared camera can be applied for temperature measurement through optical glass windows, flame temperature detection, temperature measurement through flames, and glass temperature measurement. It is suitable for applications in steel, metallurgy, glass furnace processing control, and condition monitoring, ensuring the reliability of production processes and providing supports for production with efficient operation in industrial monitoring.
Key Features:
Application :
1.Steel and Metallurgy:
Real-time monitoring of furnace temperature, flame condition, and molten metal surface temperature during high-temperature smelting processes to ensure production safety and improve product quality.
2.Glass Manufacturing: Used for temperature monitoring in glass furnaces, directly measuring molten glass temperature through optical glass windows to optimize furnace processes, reduce energy consumption, and lower defect rates.
3.Production Control: Real-time monitoring temperatures during high-temperature processing, such as heat treatment, forging, and welding, to ensure processing quality and efficiency.
4.Monitoring: Real-time monitoring of the operating conditions of industrial equipment to prevent failures and safety incidents caused by overheating, enhancing the reliability and stability of equipment operation.

Kindly reminder:
|
Interface |
Description |
| D+, D- | RS485 output |
| DC12V | Power input DC12V |
| GND | Ground (Power Ground) |
| VIDEO | Analog video signal |
| OUT | Output trigger signal; this signal should comply with the 3.3V LVTTL level specification |
| IN | Input trigger signal; this signal should comply with the 3.3V LVTTL level specification, triggered on the falling edge |
| LENSA | DC motorized lens input A |
| LENSB |
DC motorized lens input B |
| Model | MW320 | MW640 |
| Detector | ||
| Detector Type | Uncooled Focal Plane | Uncooled Focal Plane |
| Wavelength Range | 3~5um ; Optional:Â 3.9umă4.26ÎŒm and other bands |
|
| Resolution | 320Ă240 | 640Ă480 |
| Frame Rate | 50Hz | 25Hz |
| Temperature Measurement and Image Performance | ||
| Temperature Measurement Range | See the next section âMW320(640) Temperature Measurementâ | |
| Temperature Measurement Accuracy | ||
| NETD | ||
| Field of View | See the next section âMW320(640) Field of Viewâ | |
| Angular Resolution | ||
| Focusing Method | Manual | |
| Image range | 0.3m to â (the near-end distance of some lens models may be slightly larger) | |
| Emissivity and                                       Background Temperature Correction | Automatically corrects based on input emissivity and background temperature, emissivity adjustable from 0.01 to 1 | |
| Filter or Window Transmittance Correction | Automatically corrects based on input transmittance | |
| Atmospheric Transmittance Correction | Automatically calculates atmospheric transmittance based on meteorological parameters and corrects temperature | |
| Â Mouse Temperature Measurement | Real-time display of cursor point temperature | |
| Temperature Measurement Modes | Supports various temperature measurement modes, including global high/low tracking, global average temperature, point, line, rectangle, circle, ellipse, polygon, etc. Up to 100 measurement objects can be added. All measurement objects can independently set alarm threshold range, sampling period, and plot historical temperature curve. |
|
| High/Low Temperature Alarm | Audio and visual alarms on control end, logs recording, automatic storage of temperature data and image snapshots when alarm is triggered. Camera-side alarm output switch signal. |
|
| Auxiliary Temperature Analysis | Relative temperature analysis, temperature histogram analysis, historical temperature curve, online temperature curve. | |
| Image Freeze | Supported | |
| Display Enhancement | Auto stretch ; With DDE (Digital Detail Enhancement); Adjustable image brightness and contrast; Supports manual histogram stretching. |
|
| Color Palette | White hot, black hot, iron red, rainbow etc. about 12 types | |
| Digital Zoom | 2X, 4X and full screen display | |
| Data Storage | ||
| Report Generation | Word format, with content selection guide | |
| Temperature Measurement Objects | Measurement object configurations can be saved to a file and loaded from a file. Representative temperature data (for example: maximum temperature)Â for each object can be saved to a file. | |
| Temperature Data Storage | Custom MGT format can be processed with offline analysis software, CSV format can be viewed in Excel. | |
| Temperature Data Stream Storage | Custom MGS format ,and maximum size can be limited. | |
| Temperature Data Stream Playback | Playback with timestamps; Adjustable playback speed, freeze, loop playback; Image processing can be performed during playback, and super-resolution images can be output. |
|
| Infrared Image Storage | BMP or JPG format, with optional marking information | |
| Video Storage | MPEG compression, with optional user marking information | |
| Operation Log | Automatic recording and saving | |
| Network Connection | ||
| Data Interface | 1000M Ethernet, RJ45 interface | |
| Low-level Protocol | TCP, UDP, IP, DHCP, ARP, ICMP, IGMP, etc. | |
| Application Layer Protocol | RTP, RTCP, RTSP, ONVIF, FTP, Modbus TCP, GigE Vision, SIP(GB28181), etc. | |
| Environmental Parameters | ||
| Operating Temperature | -10~60â, refer to the section âMW320(640) Temperature Measurement Ranges.â | |
| Storage Temperature | -40~80â | |
| Humidity | â€85% (non-condensing) | |
| Protection Level | IP54 | |
| Shock | 25G, IEC68-2-29 | |
| Vibration | 2G, IEC68-2-6 | |
| Electromagnetic Compatibility | Complies with CE/FCC standards | |
| Electrical Interface | ||
| Temperature Data | 100M Ethernet, RJ45 interface | |
| Analog Video | Optional: PAL format or with temperature measurement area display | |
| Serial Port | RS485, can control PTZ (pan-tilt-zoom) | |
| I/O | Inputs for FFC trigger, image capture trigger, detection trigger, outputs for alarm indication etc., | |
| Power Supply | DC 12V, POE module is optional | |
| Power Consumption | 2.5W | |
| Other | ||
| Dimensions | 47(L)x45(W)x43(H)(without lens) | |
| Weight | 100g (without lens) | |
| Mounting Interface | Â M3 threaded interface, equipped with a tripod adapter. | |
| Temperature Measurement Range | NETD | Temperature Measurement Accuracy |
Ambient Temperature | Mark |
| 300~1000â | <300mk@500â | ±2â or ±2% | -10~50â | Standard |
| 500~1600â | <500mk@500â | ±2â or ±2% | -10~50â | High Temperature Type |
| 600~2300â | <500mk@1000â | ±2â or ±2% | -10~50â | High Temperature Type |
| Model | Lens Focal Length | Field of View | Angular Resolution |
| MW320 | 15mm | 28° x 21.6° | 1.47mrad |
| 25mm | 16.2° x 12.2° | 0.88mrad | |
| MW640 | 25mm | 25° x 19° | 0.68mrad |